Keygen earmaster; crack para pc tool file recover; talismania keygen crack. MARIA DEUTSCHER guizmovpn crack deb crack software blogspot 2014 - 2 DAYS. 2018-9-12 Purchase Information. We distribute our software worldwide directly through our Online Store. Please use the shopping cart icons below to be taken to the store.
Large-volume cubic high-pressure apparatus is commonly used to produce synthetic diamond. Due to the high pressure, high temperature and alternative stresses in practical production, cracks often occur in the carbide anvil, thereby resulting in significant economic losses or even casualties. Conventional methods are unsuitable for crack detection of the carbide anvil. This paper is concerned with acoustic emission-based crack detection of carbide anvils, regarded as a pattern recognition problem; this is achieved using a microphone, with methods including sound pulse detection, feature extraction, feature optimization and classifier design. Through analyzing the characteristics of background noise, the cracked sound pulses are separated accurately from the originally continuous signal. Subsequently, three different kinds of features including a zero-crossing rate, sound pressure levels, and linear prediction cepstrum coefficients are presented for characterizing the cracked sound pulses. The original high-dimensional features are adaptively optimized using principal component analysis.
A hybrid framework of a support vector machine with k nearest neighbors is designed to recognize the cracked sound pulses. Finally, experiments are conducted in a practical diamond workshop to validate the feasibility and efficiency of the proposed method. Introduction Synthetic diamond has unique physical and chemical characteristics, such as hardness, semi-conductivity and high thermal conductivity. In China, synthetic diamond is commonly produced by large-volume cubic high-pressure apparatus, which has three pairs of tungsten carbide anvils, as shown in.
When the apparatus is in operation, it provides 5 GPa pressure and 1500 °C temperature, which is required for the growth of diamond through six hydraulic rams and electric heating mode. Large-volume cubic high-pressure apparatus. ( a) Appearance; ( b) internal anvils. Nowadays, the total amount of cubic apparatuses has reached about 6000 in China. Due to the high pressure, high temperature and alternative stresses, the carbide anvil is highly prone to material fatigue.
A common form of the failure is cracking, including nucleation, propagation and fragmentation. If the released energy is less than a critical value, the crack does not grow; otherwise, it grows spontaneously. When a cracked anvil is still operating, an unbalance force is exerted on the other five anvils. If not found early enough, it is extremely easy for a cracked carbide anvil to have a serious blowout or even cause casualties. The destruction of tungsten carbide anvils due to blowouts has become one of the most significant economic losses for the manufactures since the apparatuses have a value of 0.05 g/carat.
Traditionally, regular maintenance and subsequent maintenance methods have been applied in synthetic diamond production. During downtime, the anvil is overhauled by observing or sweeping the surface with a saw blade. While in the production process, the currently available detection method is manual monitoring by experienced workers, seriously influenced by strong background noise. In conclusion, these methods lack the ability to accurately judge the state or analyze the health of the carbide anvil, thereby causing poor reliability and inaccuracy. To adequately protect the rest of the anvils prior to a blowout and improve the market competitiveness and production safety, conducting on-line crack detection of the tungsten carbide anvils is necessary.
When a crack occurs in the material, it results in a rapid release of energy, transmitting in the form of an elastic wave, namely acoustic emission (AE). The AE-based detection method has been intensively used in nondestructive assessments of cracks ,.
Caesarendra et al. Proposed an AE-based method for low speed reversible slew bearings, including AE signal processing, feature extraction and pattern classification. Rabiei and Modarres revealed a log-linear relationship between the AE features and crack growth rate, and presented an end-to-end approach for structural health management.
Presented a comparative study of the damage level diagnostics of gearbox tooth using AE and vibration measurements; the results indicated that vibration signals were easily affected by mechanical resonance, while the AE signals showed a more stable performance. Studied defect detection of rails using AE and wavelet transform at a high speed. In the above methods, the AE sensors are usually attached to the surface of the monitoring object. This is not suitable for crack detection of the carbide anvil because of the high temperature and limited inner space in the apparatus. More recently, some scholars introduced an AE technique for crack detection of carbide anvils using microphones and have produced in-depth studies on the criterion mechanism of the crack ,.
Successfully established a tungsten carbide anvil model based on the finite element method (FEM) and indicated that the cracks usually arise around the bevel edge. Li and Wang created a template library of cracking sounds and designed a detection device using voiceprint recognition with an accuracy of 77%. Combined the Hurst exponent and the neural network to develop a crack detection algorithm of carbide anvils. Subsequently, Yan et al. Designed a signal sampling and processing platform based on the digital signal processor and the field-programmable gate array, with a low false-alarm rate of 5.8 × 10 −4 using the sliding time window (STW) technique. This method suffers from the trade-off between the missing-alarm rate and false-alarm rate, with 24 cracked samples misclassified as normal ones among 63 testing samples.
The recognition rate is 95% when combined with the STW technique, which takes cost of the real-time performance into account. A more practical crack detection method is still lacking. Aiming to improve recognition accuracy and generalization, a novel crack detection method based on acoustic emission and pattern recognition is proposed.
In this method, the cracked sound pulses are firstly separated from the original signal by preprocessing. According to the mechanism of the crack, three different kinds of features are presented. The high-dimensional features are reduced adaptively by using principal component analysis (PCA). The algorithm combines a k-nearest neighbor (kNN) classifier with a support vector machine (SVM) to refine the classification outcome. Finally, experiments are carried out in a practical synthetic diamond workshop to validate the feasibility and efficiency of the proposed method. The remainder of the paper is organized as follows. Presents the principle of the acoustical crack detection method of the carbide anvil based on acoustic emission and pattern recognition.
The effectiveness of the proposed method is supported by the experimental work described in. Finally, conclusions are drawn in. Preprocessing In practical application, there are many normal sound pulses mixed in with background noise, such as knocking, hydraulic cylinder operation noise and so on. Shows the waveform and time-frequency presentation for a normal sound pulse and a cracked one. Clearly, the power spectrum of background noise is mainly below 5000 Hz, while the normal and cracked sound pulses distribute in higher frequency, reaching more than 32,000 Hz.
The duration of a cracked sound pulse is much shorter, lasting less than 64 millisecond (ms). Extract Valid Sound Pulses The high-pass filter makes the small sound pulse more visible. However, there still exists residual noise, which has slight effects on the location of the sound pulse.
To find the start and end coordinates of the sound pulses accurately, the threshold of residual noise should be estimated. Firstly, randomly select a continuous filtered signal and divide it into equal segments. Some of the segments contain sound pulses, while the others do not. They have a remarkable difference in energy. Secondly, calculate the energy of all segments and select the segments with the energy below a predefined threshold Q. The average energy E of residual noise can be calculated. (1) where N 1 denotes the length of segment; P denotes the number of objective segments, X i, j denotes the i-th objective segment.
The initial threshold of noise is set as T = E + K, where K is a positive constant, equaling the minimum energy between the sound pulses and residual noise. Parameters Q and K are specific to experiments. In practice, the noise is actually time-variant, which also affects the location of the sound pulse. Thus, a fixed threshold is not suitable; instead, a real-time renewal mechanism is designed. When the average energy of new signal F n e w is greater than the previous threshold T, it remains constant; otherwise, it is updated by Equation (2).
(3) where m = 1, 2, N 2, N 2 denotes the length of the signal; the sign function is sgn x = 1 x ≥ 0 − 1 x. Frequency representation of the cracked sound pulses in combination with normal ones. The measuring acoustic signal is equivalent to the convolution of the excitation and transfer function. When a crack occurs, the transfer function between the anvil and measuring microphone changes consequently.
The linear prediction cepstrum coefficients (LPCCs) stand for the linear prediction coefficients in the cepstrum domain, reflecting the vocal tract by the logarithmic spectrum envelope of the signal in speech recognition. Thus, the LPCC is introduced to remove the excitation, which provides a robust and reliable solution for estimating the transfer function. In the linear prediction analysis, the current signal is predicted by the linear weighted sum of the past points as. Feature Optimization The redundancy inevitably exists in the feature vector, thereby affecting the accuracy of the classification. Besides, the use of all of the features leads to the problem of high dimensionality and high computational cost.
The PCA focuses on a the linear projection of high dimensional data onto low-dimensional subspace by using least-square decomposition while maintaining the maximum variance. This technique is most widely used due to its comparably low computational costs, both in memory and computation time, and its robustness against white noise.
Thus, the cracked feature optimization was implemented with the PCA. Firstly, calculate the mean-subtracted feature matrix H by centralizing the matrix B as. Experiment and Discussions To validate the effectiveness of the proposed method, experiments are conducted in the practical synthetic diamond workshop in Henan Golden Canal Group Co., Ltd. The measuring microphone, B&K 4189, is mounted at one operation port of the apparatus by a bracket, as shown in. The acoustic signal is recorded by the B&K Pulse. The normal sound pulses are directly collected from the apparatuses in regular operation, consisting of pressurization, maintaining pressure and decompression pressurization; moreover, these apparatuses continuously work well after a long time.
The cracked sound pulses are recorded from experimental apparatus preinstalled on six cracked anvils. Shows a cracked anvil with serious surface damage caused by the crack, the location of which is marked by a circular red line. It is noted that the cracked sound pulses are confirmed and labeled by playbacks and discussions with experienced workers.
The cracked anvil. The choice of sampling frequency is based on the following considerations. In practice, the cracked sound pulses can be distinguished from the normal ones through artificial hearing (20 Hz–20,000 Hz).
This means the upper sampling frequency of the measuring signal only needs to be 40,000 Hz. However, the applied B&K Pulse can only adjust the sampling frequency to 8192 Hz, 16,384 Hz, 32,768 Hz, 65,536 Hz or 131,072 Hz. Thus, the 65,536 is finally chosen. The parameters in the sound pulse detection algorithm are listed in. Shows an example of the cracked sound pulse extraction from a continuous signal recording from the apparatus preinstalled on six cracked anvils. Clearly, three cracked sound pulses are located at about 0.35 s, 1.1 s and 1.25 s and are indicated in the blue dashed frame.
Compared to the last two pulses, the first one is covered up by significant background noise as shown in subgraph (b); however, it becomes more obvious by using a 5000 Hz high-pass filter. The start and end coordinates are located by comparing the average amplitude and threshold of energy. Besides, some sound pulses are still observed from the filtered signal, as shown in subgraphs (a) and (c). These sound pulses do not match the criteria of duration and average energy as illustrated in, thus they are discarded. This confirms that the proposed method extracts the cracked sound pulses effectively. The results of feature extraction.
( a) ZCR; ( b) SPLs; ( c) LPCCs. As shown in a, the ZCR of normal sound pulses is stable with the predominant value at about 0.38, while the cracked ones have a greater value, distributed over a larger interval 0.3, 0.55. This indicates that the cracked sound pulse has more energy in a high frequency band, and the ZCR has an ability to distinguish cracked sound pulses from normal ones. Besides, there is a slight overlap between the normal and cracked sound pulses. With an increase in the number of samples, the overlaps become more serious due to the dispersion and randomness. B shows the SPLs in the 1/6 octave frequency band 500 Hz, 32,768 Hz.
Since the cracked sound pulses may have a short duration of 16 ms, the SPLs below 500 Hz do not exist. Compared to the normal sound pulses, distinct peaks exist in cracked ones, e.g., the 1/6 octave frequency bands 5339 Hz, 5993 Hz, marked by a dashed rectangle. Besides, the SPLs for a majority of the cracked sound pulses have a greater value in the frequency band above 10 kHz. It should be pointed out that this phenomenon does not always exist. In terms of the 1/6 octave frequency band, 35 SPL features are extracted from a sound pulse. C depicts the results of the thirteenth-order LPCCs, the average value of which is described by marked lines.
Obviously, the second-order coefficient for the cracked sound pulses ranges from −0.2 to 0.4, which is different from the normal ones. There are randomly some slight differences at other orders. Since the first-order LPCC has no practical relevance, with a value of one, the other 12 LPCC features are extracted to characterize the sound pulses. Finally, 48 high-dimensional raw features, consisting of ZCR, 35 SPLs and 12 LPCCs, are extracted. Plots the results of the feature reduction by the PCA. It can be seen that the CCR significantly increases when the number of principal components rises from one to three, reaching 71.26%.
It indicates that three low-dimension principal components contain the most information in sound pulses. Then, the increasing trend gradually flattens due to a reduced amount of information contained in the principal components. When the number increases to 14, the CCR reaches 90.02%.
Subsequently, the CCR improves by only 10%, with the number of principal components rising from 14 to 48. A proper number of the principal component is determined by the trade-off between CCR and data simplification. In this way, the feature dimension is reduced significantly. The cumulative contribution rate (CCR) with the increase of the principal components.
The selected principal components are used as an input feature vector of the SVM-kNN classifier. In the algorithm, to decrease the false alarm rate, λ 1 is set greater than λ 2 as λ 1 = 5, λ 2 = 3; k is set to one-third of the total support vectors; ε is set as 0.5. The kernel parameter γ of the radial basis function and penalty factor c are optimized by a grid search with a 3-fold cross validation. For example, 70% of the normal and cracked samples is randomly selected as a training set, and the others are selected for testing. Gives the optimization results with c as abscissa and γ as ordinate, with the values ranging from 2 −5 to 2 5. The numbers in squares represent the classification accuracy. Results of the parameter optimization in the SVM classifier.
It can be seen from that the accuracy reaches a maximum and then decreases with the increase of the penalty factor when the kernel parameter is fixed. It is clear that the best accuracy is 99.68% among 121 ( c, γ) pairs. To avoid over-fitting and improve recognition accuracy on the testing set, the minimum pair (0.5, 1) is chosen among five candidate pairs with the same value of 99.68%.
Shows the classification results using the SVM-kNN classifier with different proportions of the training set and five representative numbers of the principal components, being values of the 3, 5, 10, 14 and 48. Clearly, there is a high accuracy of more than 98.8% for all conditions.
The curve of the three principle components overlaps with the one of five principal components. Their accuracies increase rapidly and then remain constant, with an accuracy of 100% with the proportion rising from 45% to 90%. When the number of principal components is 10, 14 or 48, their accuracies slightly decrease randomly after reaching the highest value of 100%. Classification results of the SVM-kNN classifier with different principal components.
Obviously, the performance of the SVM-kNN classifier does not improve with an increase of principal components. Taking three principal components as an input feature vector, plots the distribution of training samples, with a proportion of 70%, and the trained classification surface in the three-dimensional coordinate. The number of normal support vectors is 25; the number of cracked support vectors is 26.
The normal sound pulses well aggregate, while the cracked ones scatter. They are classified by the hyperplane, with an accuracy of 100%. Conclusions This paper presents an acoustical crack detection method of the carbide anvil based on pattern recognition and the AE signal.
By using the noise pretreatment and real-time renewal mechanism, the sound pulse can be separated accurately from the original signal; even the small one becomes more visible. Three kinds of extracted features, ZCR, SPLs and LPCCs, characterize the differences between cracked sound pulses and the normal ones.
Feature optimization not only reduces the computation complexity but also obtains a high classification accuracy. The designed hybrid SVM-kNN classifier has a better performance than the stand-alone SVM. The proposed method is verified by the experimental data in a practical synthetic diamond workshop. It is found that the proposed algorithm is able to significantly recognize the cracked anvil, with an accuracy of more than 99%.